ATP Bioluminescence a Means for Assessing Trailer Cleanliness
Posted in: Pork Insight Articles, Prairie Swine Centre by admin on December 19, 2016
Proper washing and disinfection of swine transport trailers is an important step in maintaining biosecurity. This study examined the feasibility of using adenosine triphosphate (ATP) bioluminescence as a rapid and effective swine trailer cleanliness assessment tool. Samples were taken from newly-cleaned, dry trailers using an ATP swab by swabbing an area of 10 cm x 10 cm and were tested for microbial contamination level using an ATP bioluminescence meter.
The results obtained from ATP testing were compared to the co-located samples taken using standard microbiological techniques with MacConkey and R2A agar contact plates (diameter Ø = 60 mm). From a total of more than 500 samples collected from 16 commercial swine transport trailers across Saskatchewan, a significant correlation (r = 0.206; p=0.001) was found between ATP bioluminescence method and standard microbiological technique using R2A agar plates. Lower correlation (r = 0.154; p=0.002) was observed between ATP method and MacConkey agar plate counts. Unlike R2A that detects a wider group of bacteria, MacConkey agar supports only the growth of selected gram-negative bacteria while ATP bioluminescence detects ATP from both microbial and organic sources.
Assessing the effectiveness of swine transport trailer cleaning protocol using ATP bioluminescence method threshold values were established with readings of less than 430 RLU per 100 cm2 as ‘Pass’ while higher than 850 RLU per 100 cm2 as ‘Fail’ or has high risk of disease propagation. With these assessment criteria, ATP bioluminescence method can be used as a supplementary tool for monitoring surface cleanliness of transport trailers in a rapid, simple, inexpensive and reliable way, to complement the procedures specified in CSHB (2011) guidelines.
http://prairieswine.com/rsc/wp-content/uploads/2018/10/ATP-Biolumenescence.pdf